Browse All FAQs

NMEA 2000 EP's - Electronic Probe Sensors

General NMEA 2000 Compatible Sensor Information

Electronic Probe connector  Pin Out

Older Electronic Probes had blue connectors.  Newer EP's use red connectors.  Adapters are available here.
All Electronic Probes require another compatible unit or gauge to display the information
Do not have power cables. Power is obtained by the NMEA 2000 Network
NMEA 2000 compatible gauges and units may require a minimal software version to operate. Check here for unit software information

 

EP-10 INFORMATION

FUEL FLOW SENSOR

Discontinued Product

Replaced by EP-60R

Click here to view or download the manual!

 
Compatible with what units?Click here for list.
Cable Length10 Ft
Fuel Line Diameter3/8" (9.5 mm) Inside Diameter
Flow Rate MeasuredOptimized for 0.6-45 Gal/hr but can measure outside these values
Added Back Pressure to the fuel system.0.5 PSI at 20 Gal/hr; 1 PSI at 40 Gal/hr
Installation LocationAbove the max level of the fuel tank, in-line after the fuel filter and any Y's or T's in the line
PackageThe EP-10, LowranceNet T and 2 (two) 1" hose clamps
Fuel TypeGasoline only. The EP-10 does not operate diesel engine fuel systems.
Hole required to route through a bulkhead.7/8" (22mm)
Multiple EP-10 sensors possible?Yes
Manufactured2005-2006

 

EP-15 INFORMATION

FLUID LEVEL SENSOR

Discontinued Product

Replaced by EP-65R

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length18" from connector to smart module. 10ft from module to end of cable
Wires  connect to:Existing fluid level arm or potentiometer
Resistance values of operation.33 (full) to 240 (empty) Ohms
FluidsAny fluid container with a proper fluid level arm (Fuel, Oil, Water, etc..)
Hole required to route through a bulkhead7/8" (22mm)
PackageThe EP-15 and a LowranceNet T
Multiple EP-15 sensors possible?Yes
Manufactured2005-2006

 

EP-20 INFORMATION

SUZUKI ENGINE INTERFACE

Designed to interface with Suzuki Engines as the Suzuki data provided to the network is not NMEA 2000.

Please call the Suzuki Customer service line at 714-572-1490, Suzuki’s part number for the engine interface is 990C0-88034. 

The Suzuki Engine Interface provides the following information over the NMEA 2000 network. 

 

  • Engine RPM
  • Alternator Voltage
  • Engine Hours
  • Fuel Flow
  • Engine Trim
  • Fuel Used
  • Trip Fuel Used
  • Seasonal Fuel Used
  • Speed over water (DF300 Only)
  • Water Pressure (DF300 Only)
  • Current Gear (DF300 Only)
  • Standard Diagnostics
    • Overheat
    • Low Oil Pressure
    • Over Rev
    • Low Battery Voltage

 

 

EP-25 INFORMATION

Water speed SENSOR

Discontinued Product

Replaced by EP-70R

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length18" from connector to smart module. 10ft from module to end of cable
Mounting LocationTransom
Hole required to route through a bulkhead7/8" (22mm)
PackageThe EP-25 and a LowranceNet T
Multiple EP-25 sensors possible?Yes
Manufactured2005-2006

 

EP-30 INFORMATION

BENNETT TRIM TAB ANGLE MONITOR

Available through Bennett Marine. 

 Click here for Bennetttrimtabs.com

 

EP-35 INFORMATION

Temperature Sensor

Discontinued Product

Replaced by EP-80R

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length18" from connector to smart module. 10ft from module to end of cable
Temperature Range4-176ºF (-20-80 ºC)
PlacementAnywhere temperature is to be monitored
PackageThe EP-35 and LowranceNet T
Multiple EP-35 sensors possible?Yes
Manufactured2006

 

EP-35 TH INFORMATION

Thru-Hull Temperature Sensor

Discontinued Product

Replaced by EP-80R TH

READ AND UNDERSTAND THE ENTIRE MANUAL BEFORE DRILLING A HOLE IN THE BOTTOM OF ANY BOAT!

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length10ft
Temperature Range4-176ºF (-20-80 ºC)
Max Hull Thickness for installing the EP-35 TH1-1/4" (31 mm)
Hole size required to mount through the hull1-1/16" (27 mm) listed. Smaller size hole works better (1")
PackageThe EP-35 TH, locking nut, LowranceNet T. Gasket or sealant is not provided, supplied by installer.
Multiple EP-35 TH sensors possible?Yes
Manufactured2006

 

EP-50 INFORMATION

storage device

Discontinued Product

Replaced by EP-85

stores engine ssettings on select nmea 2000 compatible engines.

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length1.5 ft
Mounting LocationAnywhere
PackageAvailable only with OEM installations.
Multiple EP-50 sensors possible?Yes
Manufactured2007

 

EP-60R INFORMATION

FUEL FLOW SENSOR

Replaces  EP-10

Click here to view or download the manual!

 

 

Compatible with what units?Click here for list.
Cable Length10 Ft
Fuel Line Diameter3/8" (9.5 mm) Inside Diameter
Flow Rate MeasuredOptimized for 0.6-45 Gal/hr but can measure outside these values
Added Back Pressure to the fuel system.0.5 PSI at 20 Gal/hr; 1 PSI at 40 Gal/hr
Installation LocationAbove the max level of the fuel tank, in-line after the fuel filter and any Y's or T's in the line
PackageThe EP-60R, LowranceNet T and 2 (two) 1" hose clamps
Fuel TypeGasoline only. The EP-60R does not operate diesel engine fuel systems.
Hole required to route through a bulkhead.7/8" (22mm)
Multiple EP-60R sensors possible?Yes (Up to 3 engines)
Manufactured2007-2012

 

EP-65R INFORMATION

FLUID LEVEL SENSOR

Replaces  EP-15

Click here to view or download the manual!

 

Compatible with what units?Click here for list.
Cable Length18" from connector to smart module. 10ft from module to end of cable
Wires  connect to:Existing fluid level arm or potentiometer
Resistance values of operation.33 (full) to 240 (empty) Ohms
FluidsAny fluid container with a proper fluid level arm (Fuel, Oil, Water, etc..)
Hole required to route through a bulkhead7/8" (22mm)
PackageThe EP-65R and a LowranceNet T
Multiple EP-65R sensors possible?Yes
Manufactured2007-2012

 

EP-70R INFORMATION

Water speed SENSOR

Replaces  EP-25

Click here to view or download the manual!

 

Compatible with what units?Click here for list.
Cable Length18" from connector to smart module. 10ft from module to end of cable
Mounting LocationTransom
Hole required to route through a bulkhead7/8" (22mm)
PackageThe EP-70R and a LowranceNet T
Multiple EP-70R sensors possible?Yes
Manufactured2007-2012

 

EP-80R INFORMATION

temperature SENSOR

Replaces  EP-35

Click here to view or download the manual!

 

Compatible with what units?Click here for list.
Cable Length18" from connector to smart module. 10ft from module to end of cable
Temperature Range4-176ºF (-20-80 ºC)
PlacementAnywhere temperature is to be monitored
PackageThe EP-80R and LowranceNet T
Multiple EP-80R sensors possible?Yes
Manufactured2007-2012

 

EP-80R TH INFORMATION

Thru-Hull Temperature Sensor

Replaces  EP-35 TH

READ AND UNDERSTAND THE ENTIRE MANUAL BEFORE DRILLING A HOLE IN THE BOTTOM OF ANY BOAT!

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length10ft
Temperature Range4-176ºF (-20-80 ºC)
Max Hull Thickness for installing the EP-35 TH1-1/4" (31 mm)
Hole size required to mount through the hull1-1/16" (27 mm) listed. Smaller size hole works better (1")
PackageThe EP-80R TH, locking nut, LowranceNet T. Gasket or sealant is not provided, supplied by installer.
Multiple EP-80R TH sensors possible?Yes
Manufactured2007-2012

 

EP-85 INFORMATION

storage device

Replaces  EP-50

stores engine ssettings on select nmea 2000 compatible engines.

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length1.5 ft
Mounting LocationAnywhere
PackageAvailable only with OEM installations.
Multiple EP-85 sensors possible?Yes
Manufactured2007-2012

 

EP-90 INFORMATION

pressure sensor

provides pressure data such as atmospheric, engine boost, engine oil, engine water, fuel, transmission oil, and pitot speed.

Click here to view or download the manual!

Compatible with what units?Click here for list.
Cable Length1.5 ft
Mounting LocationAnywhere
Maximum Pressure100 PSI (689 kPa)
Multiple EP-90 sensors possible?Yes
Manufactured2009-2012

 

LGC-4000 INFORMATION

GPS Receiver

Replaces LGC-3000

Click here to view or download the manual!

Compatible with what units?

Click here for list.

 

We value your feedback. Was this article useful?

  • E-mail address:


Email this article to a friend.

Please complete the form below to email this article to a friend.

Items marked with an * are required.

  • Email:
  •  
 

Quick Links

My Portal

Contact Us